ABV Calculator

ABV = (OG − FG) × 131.25, so OG 1.050 and FG 1.010 give 5.25% ABV. For strong beer and wine the alternate formula 76.08 × (OG − FG) / (1.775 − OG) × FG / 0.794 reads higher: 5.34% here.

Brix and SG

Convert from

Hydrometer temperature correction

Temperature unit

Readings are estimates. Brix conversion is for unfermented wort, must or juice.

Did this solve your problem?
Prefer us on Google

How to use

  1. Enter the original gravity (before fermentation) and the final gravity (after) as specific gravity, for example 1.050 and 1.010. You get ABV from both formulas and the apparent attenuation.
  2. To convert a refractometer or must reading, type the Brix value, or switch to SG to go the other way. Use it for unfermented wort or juice only.
  3. If the sample was not at the hydrometer's calibration temperature, enter the reading, the sample temperature and the calibration temperature printed on the hydrometer (often 20 °C / 68 °F or 15.6 °C / 60 °F). Use the corrected value as your OG or FG.

How it works

Standard: ABV = (OG − FG) × 131.25. Alternate: ABV = 76.08 × (OG − FG) / (1.775 − OG) × (FG / 0.794). The alternate formula follows the curve better above about 7 to 8% and is the one to check for barley wine, mead or wine. Apparent attenuation = (OG − FG) / (OG − 1) × 100. Both ABV formulas are as published by Brewer's Friend.

Brix to SG: SG = 1 + Bx / (258.6 − Bx / 258.2 × 227.1). SG to Brix: Bx = ((182.4601 × SG − 775.6821) × SG + 1262.7794) × SG − 669.5622. Degrees Plato are within about 0.1 of Brix, so the same number is shown.

Temperature correction: corrected SG = reading × f(T sample) / f(T calibration), with f(T) = 1.00130346 − 0.000134722124 T + 0.00000204052596 T² − 0.00000000232820948 T³ and T in °F. This polynomial fits the density of water and is valid from 0 to 71 °C.

Sources: Brewer's Friend ABV Calculator · Brewer's Friend Brix Converter · HomeBrewTalk: Temp correction formula for hydrometerLast reviewed 2026-10-21

FAQ

Which ABV formula should I trust?

For normal strength beer the two agree within about 0.1%. Above 1.070 OG they drift apart and the alternate formula is closer to lab results, so use it for strong beer, mead and wine.

Can I use Brix from a refractometer after fermentation?

Not directly. Alcohol bends light too, so a refractometer reads too high once fermentation starts. Use a hydrometer for the final gravity, or a dedicated refractometer correction.

How much does temperature change a hydrometer reading?

A 1.050 sample at 30 °C read on a 20 °C hydrometer is really about 1.0526. Below the calibration temperature the true gravity is a little lower than the reading.

What do the gravity points mean?

Brewers drop the 1 and multiply by 1000: SG 1.048 is 48 points. The temperature correction is shown in points.